| Product model: | EX-600-G |
| Product Texting: | Testing Ethylene oxide in air |
| Sensor type | Electro -chemical sensor |
| Tested reagents: | 0-100%LEL |
| Resolution: | 0.1%LEL |
| Display mode: | LCD display |
| Temperature: | Wet degree accessories, Temperature measuring range: -40 to 70 DEG C, Humidity detection range: 0-100%RH |
| Detection accuracy: | diffusion, circulation, pump suction | Optional installation: | wall hanging, pipe type |
| Detection accuracy: | ≤±2% | Linear error: | ≤±1% |
| Response time: | ≤3s(T90) | Zero drift: | ≤±1%(F.S/years) |
| Recovery time: | complex | Complex | ≤±1% |
| Signal output: | - 4-20mA signal: 16 bit precision 4-20mA chip output standard, the transmission distance of 1Km
- The switch signal: standard 2 optional relay, third relay, passive relay contact capacity, 220VAC 3A/24VDC 3A
|
| Transmission mode: | - Cable transmission: 3 core, 4 core cable, long-distance transmission (1-2 km)
- The GPRS transmission: built-in GPRS module, real-time remote data transmission, not limited by the distance (optional)
|
| Receiving equipment: | User computer, Control alarm, PLC, DCS and so on |
| Alarm mode: | On-site sound and light alarm, external alarm, remote controller alarm, computer data acquisition software, alarm and so on |
| Alarm setting: | Standard configuration, two alarm, optional three alarm, alarm can be set up: routine alarm, alarm interval control |
| Electrical interface: | 3/4 "NPT internal thread", "1/2" NPT internal thread, and supports 2 kinds of electrical connections |
| Explosion proof mark: | ExdII CT6 (flameproof) | Shell material: | aluminum + sandblasting / fluorocarbon paint, corrosion and explosion proof |
| Protection grade: | IP66 | Temperature: | -30 ~ 60ºC |
| Power supply: | 24VDC(12~30VDC) | Humidity: | ≤95%RH,No condensation |
| Size weight: | 183×143×107mm(L×W×H)1.5Kg(instrument weight) | working pressure: | 0 ~ 100Kpa |
| Standard parts: | Manual, | warranty period: | 1Years |